i-32V5
12
LED
TERMINAL BLOCK
Resource Parameter
Terminal block
X
value
ST 6 H17 17.1 / 17.2 0 Not set
Analogue input congurable with an NTC-
10kΏ probe at 25°C β 3435
ST 7 H18 19.1 / 19.2 0 Not set
Analogue input congurable with an NTC-
10kΏ probe at 25°C β 3435
ST 11 H22
22.1 (gnd)
22.2 (un-
der-voltage)
0 Not set 0-10Vdc under-voltage input
ID 2 H46 16.1 / 16.2 0
Remote summer/winter mode
change
(see paragraph 10.3.2)
Voltage-free digital input.
To acvate the funcon par. 10.3.2
ID 3 H47 15.1 / 15.2 2
Remote on/o,
(see paragraph 10.3.1)
Digital input, voltage-free contact. Default
funcon acve.
ID 9 H53 20.1 / 20.2 0 Not set Voltage-free digital input
DO 3 H81
6.1 (phase)
6.2 (neutral)
22
Plant integraon heater
control
230Vac, 50Hz, 2A (AC1) live output
(see paragraph 10.5.1)
DO 6 H84
11.1 (phase)
11.2 (neutral)
6
DHW valve control
(see paragraph 10.2)
230Vac, 50Hz, 2A (AC1) single-phase live
output
DO 7 H85
14.1 (phase)
14.2 (neutral)
25
Double setpoint valve control
(see paragraph 10.14)
230Vac, 50Hz, 2A (AC1) live output
Modbus RTU/RS4825
communicaon
--
4.1 (gnd)
5.1 (R-)
5.2 (R+)
-- -- Factory enabled with CM accessory