5. 
Select the operang mode and manually reset any alarms.
Each me you press the key you have the following sequence:
OFF -> COOL -> HEAT -> OFF
If DHW is enabled, the sequence is the following:
OFF -> COOL -> COOL+SAN -> HEAT -> HEAT+SAN -> OFF
While seng the parameters, this key has the funcon of sending BACK by one level.
Grants access to the parameter seng menu and allows you to set the summer, winter and sanitary setpoint.
UP key. In the parameter seng mode, it allows you to move to a higher menu or to increase the parameter value when in “edit”
mode.
DOWN key. In the parameter seng mode, it allows you to move to a lower menu or to decrease the parameter value when in
“edit” mode.
MENU


MENU LABEL PASSWORD LEVEL OTHER CONDITIONS
Setpoint Set User Not accessible if connected to Hi-T2
Probes tP Installer ---
Alarms Err User Only if acve alarms
Digital input Id Installer ---
Parameters Par Installer ---
Password PSS User ---
Hours of operaons oHr Installer ---
USB USb Installer Only with pen drive with relevant update les
Versione Firmware Fir Installer Version, Revision and Sub
Alarm log Hist Installer Only if the log contains data


SETPOINT MENU

SETPOINT DESCRIPTION UNIT DEFAULT RANGE
Coo First Summer setpoint °C 7.0 5 ÷ Co2
Hea First Winter setpoint °C 45.0 25 ÷ 60
*San Sanitary setpoint °C 48.0 25 ÷ 60
Coo2 Second Summer setpoint °C 18.0 Coo ÷ 25
Hea2 Second Winter setpoint °C 35.0 25 ÷ Hea
San2 Second Sanitary setpoint °C 35.0 25 ÷ Hea
**rCoo Mixing valve Summer setpoint °C 15.0 0.0 ÷ 80