Chapter 6
Washing
37
THE MACHINE MUST NOT OPERATE WITH NO PRODUCT INSIDE IT, AS THIS WOULD RISK
DAMAGING THE ROTARY PRESSURE PUMP.
THE MACHINE MUST NOT OPERATE WITH NO PRODUCT INSIDE IT, AS THIS WOULD RISK
DAMAGING THE ROTARY PRESSURE PUMP.
4.
Disinfection phase:
After re-fitting all of the components in the machine, carry out the disinfection phase.
- Pour a disinfectant solution, at a temperature NOT HIGHER THAN 40°C,
into the reserve tub until it is ½ full.
- Position a suitable container under the dispensing tap.
- Press the “DISPENSE” button and hold it down to drain the disinfectant
solution from the tub into the container placed under the dispensing tap.
5.
Rinse
to
Remove disinfectant phase:
Follow the instructions on the disinfectant packaging and if necessary thoroughly rinse the machine to completely remove
disinfectant residues.
- Pour drinking water, at room temperature, into the reserve tub until it is ½
full.
- Position a suitable container under the dispensing tap.
- Press the “DISPENSE” button and hold it down to drain the rinse water from
the tub into the container placed under the dispensing tap.