OPEN STOP CLOSE
MOTOR MOTION
Matrix 1
OPEN STOP CLOSE
MOTOR MOTION
Matrix 1
learn gate positions
8
1. Push OPEN button to cycle gate to open position.
Operator cycles slowly while learning position.
2. Then push CLOSE button to cycle gate to closed position.
Operator cycles slowly while learning position.
Set to MAX
MAX
GATE SPEED
MIN
MAX
Matrix 1
After gate positions have been learned, the gate will cycle at the speed set on matrix 1 “GATE SPEED” setting.
Gate
Shut-Off
Switch
After the limit sensor activators and at least ONE entrapment sensor has been installed, put the gate in the CLOSED position:
IMPORTANT:
GATE SHUT-OFF Switch MUST be OFF.
(see page 11 for more information about switch)
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
ERD
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
ERD
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
ERD
PhotoCell
Edge
UL
Entrap
1
2
Limit SW
ON-LINE
MATRIX
JOG
JOG
LEFT
RIGHT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ERD
Motor
OverLoad
POWER
MC-200
Motor Controller
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
Edge
ERD
The ERD Sensor - Electronic Reversing Device (Type A) MUST be adjusted for the OPEN and CLOSE gate cycles.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate.
An input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate.
An input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
Limit sensors must be learned BEFORE adjusting the ERD Sensitivity.
A. Turn knob until blue LED lights up.
Maximum sensitivity reached,
Position 1 - Too sensitive for most gates.
Position 13:
Typical gate setting.
B. Turn knob counter-clockwise to
reduce gate sensitivity while testing ERD
until desired results is attained.
(LED remains OFF for all but position 1)
IMPORTANT: When satisfied
with ERD adjustment, cycle
the gate 3 or 4 times to make
sure that the ERD sensor does
not falsely trigger during
normal gate operation.
Re-adjust if this happens.
CAUTION: Position 16 results in gate exerting
MAXIMUM force before reversing direction.
Adjusting ERD:
Typical Settings:
16 sensitivity setting positions.
NO mechanical hard stop for knob.
Position 16:
Heavy gate setting.
Long gate setting.
Cantilever gate setting.
Uphill gate setting.
High wind area gate setting.
OPEN STOP CLOSE
MOTOR MOTION
Matrix 1
Adjust ERD Reverse sensor
9
If alarm sounds while adjusting ERD,
press STOP BUTTON on Matrix 1 to
shut-off alarm.
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
ERD
8
UL 325 2016 Standard-MAX Quick Install Rev 8