EasyManua.ls Logo

Maximum Controls Max Megatron 1400 - MAX BC-7 Battery Module

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
IMPORTANT
connect to
“BATTERY IN”
before use
ON/OF
F
Batt
ery
E
F
1/
2
Battery Voltage
Replac
e
Battery
TEST
Battery
Battery
I
N
Error
MAX BC-7
Battery Module
B
ATTE
R
Y
IN
PO
WER/SOLA
R
IN
P
OWER
IN
Batte
ry
Pa
c
k
TO
MO
T
O
R
C
ONTR
O
LL
E
R
ww
w.
Max.US.com
BATTERY
IN
POWER/SOLAR
IN
PhotoCell
Ed
ge
UL Entrap
1
2
Lim
it
SW
ON-LINE
MATRI
X
JOG
LEFT
JOG
RIGHT
Jog LT
Jog RT
GND
Edg
e 1
Edge
2
Ph
ot
o
Cell
ERD
Moto
r
OverLoa
d
POWER
MC-20
0
Motor Co
ntroller
16
15
14
13
12
3
4
5
MAX
LED
O
N
Ed
g
e
Sensitivity
ERD
MO
TO
R
Power In
ALARM
BATTER
Y
P
ACK
LIMIT
SWITCH
MO
TO
R
INPUTS
PWR 12V
-
GND
-
-
-
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
MA
TRIX 1
Edge 1
Monitored
Reversin
g
Edge
Monitored
Photo
Cell
OR
GND
Jog RT
Jog LT
Entrapment Protectio
n
Inputs:
MUST jumper
unused inputs
Entrapment Protection
Sensor Guideline
s
1
-
-
-
C
AUTION:
See installation instructions
.
A
TTENTIO
N:
Vo
ir la notice d’installation.
Edge 2
Photo Cell
MC-200
PWR 12
V
MUST
be used
ONLY power entrapment protection
sensors with MC-200 PWR 12
V
Inputs &
MUST be “LEARNED”
to MONI
TO
R sensors
.
T
o LEARN inputs & :
1.
MONITORED
Sensors MUST
be
wired to inputs BEFORE they can be
learned.
Any un
used in
p
uts MUST
be
jumpered.
2.
Reversing Edge and/or Ph
o
to Cell ca
n
be wired to either input 2 or 3.
3.
Press and HOLD th
e
OPEN & ST
OP
buttons at the same time on
Matrix
1
u
ntil beep is heard, learn mo
de begins
.
Learn mode lasts for 5 min. indicated
by beeping
.
4.
LEDs
WI
LL be
ON
for
e
ach detected
s
ensor on MC-200. LEDs
WILL
be
ON
for
BO
TH
MC-200s when dual
operators are used.
5.
P
ress
STOP
button again within 5 min.
to learn sensors and end learn mode,
beeping stops.
Inputs are now
MONITORED
.
2
3
2
3
2
3
A sensor
MUST
be wired to
EDGE 1
or
operator
WILL NO
T
function.
Wire NORMAL
LY CLOSED
(N.C.)
MONI
TO
RE
D sensors
ONLY, to each
operato
r’s
MC-200 when dual operators
are used
.
Reversing Edge and/or Photo Cell can
be wired to
ANY
of the
3 Inputs
.
MC-200 PWR 12V
MUST be used to
power
MONITO
RED
sensors.
UNUSED
inputs
MUST remain
JUMPERED
or fault will occur.
GND
1
2
3
OPEN STOP
CLOS
E
MOTOR MOTI
ON
MC-200 Swing
MAX MC-200 Motor Controller
Continued on next 2 pages.
Entrapment Protection Sensor Inputs
3
4
5
6
7
1
1
2
3
4
5
6
7
2
BATTERY Plug: MUST be plugged into BATTERY IN port Before use.
POWER/SOLAR IN Port: MAX Megatron Toroid box connection.
Battery Voltage LEDs: Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
ON/OFF Battery Button:
IMPORTANT: Battery power automatically turns ON when MAX Megatron
Toroid Box AC POWER Switch is turned ON.
To turn OFF ALL POWER to operator:
1. Turn OFF AC POWER Switch on MAX Megatron Toroid Box.
Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY
button until MAX BC-7 LEDs turn ON, then release button.
LEDs will turn OFF.
Replace Battery LED: Replace battery when lit.
TEST Battery Button: Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
Battery IN Error LED: Lights when there is a battery connection problem.
Make sure battery plug #1 is plugged into BATTERY IN port or there is no
damaged or loose wires.
MAX BC-7 Battery Module
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
MOTOR OVERLOAD LED: Excessive current being drawn by motor when lit.
ERD LED: ERD sensor has been activated when lit.
ERD Sensitivity Knob: 16 selectable sensitivity settings of ERD sensor.
ERD Sensitivity LED: MAX sensitivity reached when lit.
Jog LEFT/RIGHT Buttons:
Push and HOLD buttons accordingly to move the gate (release the button to
stop gate). WARNING: Avoid moving gate while using Jog buttons.
INPUTS:
Jog LT/RT inputs: Can connect to an External Open/Close Key switch.
Connect a single key switch to control dual gate operators, See page 34.
GND input: Low Voltage Common connection.
Edge 1-MONITORED CLOSING direction ONLY input: Connects to a
NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Closing direction activation: gate will reverse to full open position and
reset close timer.
Opening direction activation: gate will NOT be monitored during
opening cycle.
Edge 2-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 18).
Closing direction activation: gate will REVERSE to full open position but
will NOT reset close timer. Another command is required for gate to
resume operation.
Opening direction activation: gate will REVERSE 2 inches and STOP.
Another command is required for gate to resume operation.
Photo Cell-LEARNED MONITORED OPENING/CLOSING direction input:
Connects to a NORMALLY CLOSED (N.C.) Sensing Edge or Photocell.
Input MUST be “LEARNED” before it can MONITOR a connected sensor
(see page 18).
Closing direction activation: gate will STOP. Another command is
required for gate to resume operation.
Opening direction activation: gate will STOP. Another command is
required for gate to resume operation.
Matrix On Line LED: Gate operator is successfully communicating with
Matrix 1 when lit.
Limit SW On Line LED: Limit Switch Sensors are successfully
communicating with MC-200 Motor Controller when lit.
Edge 1 LED: Edge 1 sensor has been activated when lit.
Edge 2 LED: Edge 2 sensor has been activated when lit. LED will light up
during “LEARNING” mode when sensor is connected, see page 18.
Photocell LED: Photocell sensor has been activated when lit. LED will light
up during “LEARNING” mode when sensor is connected, see page 18.
UL Entrap LED: Edge1/Edge2/Photocell inputs have been activated when lit.
Power LED: Low voltage power is connected when lit.
RS-485 Input:
Factory wired for Primary operator.
Wire to Matrix 1 “SEC GATE” for Secondary operator ONLY.
24V Power Input: 24V Power for Matrix 1 ONLY.
12V Entrapment Protection Sensor Power Out: 12V Power that ALL
Entrapment protection sensors MUST use PWR 12V power.
A
B
C
D
E
F
G
I
L
M
N
O
P
H
J
K
Wiring operator
DUAL GATE OPERATORS NOTE: Connect EACH photocell/sensing
edge to the corresponding gate operator’s MC-200. See page 9.