20
O
N
/OF
F
Ba
tte
r
y
E
F1
/2
B
a
t
t
e
ry
Volt
a
g
e
R
e
pl
a
ce
B
atte
r
y
T
EST
B
a
ttery
B
atte
r
y IN
Er
r
o
r
M
AX BC-
7
Ba
t
t
ery
M
od
u
le
BAT
T
E
RY
I
N
P
O
WE
R
/
S
O
L
AR
I
N
P
OW
E
R
IN
Bat
t
er
y
P
ack
T
O M
OT
O
R
CO
NT
R
O
L
L
E
R
www.
Max
.
U
S.
c
o
m
B
ATTE
R
Y
I
N
I
M
POR
TAN
T
co
nne
ct to
“
B
AT
TERY
IN
”
b
efore
us
e
P
OWE
R
/SOLAR
IN
MAX BC-7
Battery Module
Low Voltage
High Voltage
Input Power
To Operator
24 VDC
Power In
Remote
Toroid 15 Amp
Connector
Pos +
GND
24V
Wires
10 AWG
Minim
um
Gr
oun
d
230V
AC
O
N
P
OW
E
R
O
F
F
MAX PS-24
P
OWE
R
SU
P
P
L
Y
F
USE
7
A
MP
IN
Mad
e
i
n USA
Sel
ec
t
I
nput
V
ol
ta
ge
:
115VAC or 230V
AC
dis
conn
ect
p
owe
r
b
ef
o
re
s
e
r
vi
c
in
g
uni
t
WARNING
HI
G
H
VOLTAG
E
!
warran
t
y
VOIDED
i
f
l
a
bel
i
s
REMOV
ED
Input AC Power Selector Switch
CAUTION: If power selector switch is
set for 115V but input power is actually
230 V, 7 Amp Fuse will blow.
DO NOT TURN POWER
ON AT THIS TIME.
Remote Toroid 15 Amp Box
Power Terminal
Wires
Line (Black)
Neutral (White)
Chassis (Green)
Input AC Powe
r
A MAX Magic Box Kit (sold separately) is required to remotely install a Remote Toroid 15 Amp box at the AC power source.
Plug in Remote Toroid 15 Amp connector to Power In at MAX Magic Box. Wire input AC power to the Toroid 15 Amp box.
Choose either 115V or 230V setting on input AC power selector switch. Run 24V low voltage wires (not included) from the
MAX Magic Box connection to the gate operator and wire to POWER/SOLAR IN connector (Polarity Matters!).
Remove the Remote Toroid 15 Amp connector from the BC-7 battery module POWER/SOLAR IN port. Plug the Magic Box
POWER/SOLAR IN connector into the POWER/SOLAR IN port.
NOTE: A MAX Magic Box kit is required for EACH gate operator
when using dual gate operators.
IMPORTANT NOTE: Maximum Control’s remote
power supply technology does NOT utilize the
battery power from the MAX BC-7 Battery
Module during NORMAL gate operation.
Battery power is reserved for back-up power
ONLY when an AC power failure occurs. As a
result, battery life is NOT shortened.
This low voltage system can CONTINUOUSLY
cycle the gate during NORMAL gate operation,
perfect for high traffic gate applications.
POWER/SOLAR IN
Port
POWER/SOLAR IN
Connector
(Included in kit).
At Gate Operator
Wiring operator
IMPORTANT: MAX Magic Box and Gate Operato
MUST EACH be Properly GROUNDED. Proper
grounding is a requirement for LIGHTNING
PROTECTION in lightning prone areas. To be
effective, ground connections should be made
with a minimum 12 AWG, 600 volt insulated
wire to a ground point within 10 feet of the MA
Magic Box and gate operator. The ground point
must be at an electrical panel, a metallic cold
water pipe that runs in the earth, or a groundin
rod.
NOTE: Beware of existing underground services.
low voltage remote power supply kit - optional
MAX Magic Box MUST be
Properly GROUNDED
Pos +
GND
Polarity Matters!
Ground
within 10 ft
of Box
NOTE: Consult city codes for AC line wiring.
24V Low Voltage Wire
in Conduit to Gate Operator
115 VAC or
230 VAC
Input AC Power
CAUTION: MAKE SURE CIRCUIT
BREAKER IS OFF AT POWER
SOURCE BEFORE WIRING
DANGER
HIGH VOLTAGE!
At MAX Magic Box
Grounding Rod