Maximum Controls Max Megatron 1400 - ADJUSTMENTS; OPEN AND CLOSE LIMITS

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
FUSE
7
A
m
p
PO
WER
11
5
VAC
3
A
max
On
Of
f
W
ARN
I
NG
:
F
o
r
co
n
t
i
n
u
e
d
p
ro
te
ct
i
o
n
a
g
a
in
st
fi
re
,
re
p
la
ce
o
n
l
y
with
th
e
sa
me
t
yp
e
a
n
d
ra
tin
g
o
f
f
u
s
e
.
A
V
ER
T
I
S
SE
MENT
:
p
o
u
r
n
e
p
a
s
co
mp
ro
me
tt
re
la
p
r
o
te
ctio
n
co
n
t
re
le
s
ri
sq
u
e
s
d
in
ce
n
d
i
e
,
u
t
i
lis
e
r u
n
f
u
si
b
le
d
e
me
s
t
yp
e
e
t
ca
ra
c
ri
st
i
q
u
e
s
n
o
mi
n
a
l
e
s.
O
N/
O
FF
Ba
tt
e
r
y
E
F1/
2
B
a
t
te
ry
Vo
l
t
a
g
e
Re
p
la
c
e
B
a
t
t
e
r
y
TEST
Ba
t
t
e
r
y
Ba
t
t
e
r
y
IN
Er
r
o
r
MAX
BC-
7
Ba
t
te
r
y
M
odu
l
e
P
h
o
t
o
Ce
ll
E
d
g
e
U
L
E
n
t
ra
p
1
2
L
i
m
it
S
W
O
N
-
L
I
NE
M
A
T
RI
X
J
OG
LEFT
J
O
G
R
I
G
H
T
J
og
L
T
J
og
R
T
GN
D
Edg
e
1
Edg
e
2
Phot
o
C
e
l
l
E
R
D
Mo
t
or
Ov
er
L
o
ad
PO
W
ER
MC
-2
0
0
Mot
or
C
o
nt
r
oll
e
r
1
6
1
5
1
4
1
3
1
2
3
4
5
M
AX
L
ED
O
N
E
d
g
e
Se
n
s
i
t
i
v
i
t
y
ER
D
MO
TO
R
Power
I
n
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
MATR
IX
BO
A
R
D
A
L
A
R
M
BA
T
T
E
R
Y
P
AC
K
L
I
MIT
SW
IT
C
H
M
OT
O
R
I
N
P
U
T
S
24V
GND
U
L
AL
AR
M
1
2
V
ALAR
M
R
E
T
R
ESE
T
G
N
D
G
A
T
E
TA
M
PER
M
AG
L
O
CK
OPE
N
RI
GHT
OP
E
N
L
E
F
T
M
AG
L
O
CK
D
ELA
Y
PR
IM
AR
Y
G
A
T
E
SAFETY
CEN
T
E
R
E
XIT
O
PE
N
M
AX
G
A
T
E
SP
E
ED
ST
O
P
CL
O
SE
ANTI
T
AI
L
G
AT
E
CL
O
S
E
T
IM
E
R
POS
I
T
IO
N
R
E
CO
R
D
ER
ID
PLU
G
AU
TO
MAT
I
C
OP
EN/CL
O
S
E
C
O
N
TR
O
LS
B
A
T
T
E
RY
BACK-
U
P
MO
D
E
MA
TRIX
1
PH
O
T
O
CE
L
L
E
D
G
E
1
E
D
G
E
2
ID
PL
U
G
ER
R
O
R
O
PE
N
CO
M
CLOSE
T
am
p
er
N
O
CO
M
G
N
D
T
am
per
IN
O
F
F
O
F
FON
E
X
I
T
P
A
R
TI
AL
O
P
EN
O
B
D
P
O
RT
B
LA
C
K
B
O
X
M
OT
OR MO
T
IO
N
CE
NT
E
R
R
E
VE
RS
E
S
E
NS
I
T
I
VI
T
Y
MO
T
O
R OV
E
RL
OA
D
NO
L
I
MI
T
S
W
I
T
C
H
/
CL
A
MP
S
L
I
P
P
I
NG
MI
N
M
A
X
12
V
DC
G
ND
24
VD
C
GN
D
M
A
X
M
IN
O
F
F
SA
FE
T
Y
L
E
A
V
E
O
P
E
N
L
E
A
V
E
CLOS
E
D
MADE
i
n
US
A
O
P
E
N
1
T
I
ME
2
S
ec
1
.
5
S
e
c
CO
M
N
C
BA
T
T
E
RY
IN
U
SE
PO
WER
G
A
T
E
ST
A
T
U
S
M
OT
OR
ON
-LINE
L
IM
IT
SW
IT
C
H
ON-
L
INE
(+
)
GN
D
(-
)
PR
I
MA
R
Y
G
A
T
E
(+
)
GN
D
(-
)
SEC
G
A
T
E
UL
E
NT
R
A
P
PHOTOCELL
GND
STRI
K
E
GND
K
EYPAD
/
RD
R
GN
D
FIRE
DEP
T
GN
D
MA
X
OPEN
GND
RADIO S
IG.
RADIO GND
OPEN
STOP
CLOS
E
CO
M
GA
TE
DISA
B
LE
Open RIGHT
The limit tabs need to be set BEFORE the gate can be cycled or DAMAGE could occur.
Approximate OPEN and CLOSED
limit tab positions.
OPEN LED
OPEN LED
CLOSED Tab
Activated
Position
CLOSED Tab
Activated
Position
OPEN Tab
Activated
Position
OPEN Tab
Activated
Position
Push and HOLD the JOG LEFT or JOG RIGHT buttons
accordingly on the MAX MC-200 motor controller to
move the gate (release the button to stop gate). This
allows gate to be moved back and fourth without leaving
the operator to “fine tune” the open and close gate
positions if desired.
Adjustments
open and close limits
CLOS
E
D
L
IMIT
OPEN
L
IMIT
Limit
Switch Box
OPEN Limit
switch contact
point.
CLOSED Limit
switch contact
point.
IMPORTANT: Manually Release arm and move the
gate to the desired OPEN and CLOSED positions to
adjust the limit tabs. Make sure power is ON.
A
r
m
O
p
e
n
i
n
g
D
i
r
e
c
t
i
o
n
A
r
m
O
p
e
n
i
n
g
D
i
r
e
c
t
i
o
n
Arm Closed Position
Arm Closed Position
Arm Open Position
Arm Open Position
Open Limit Switch
Closed Limit Switch
CLOSED LED
CLOSED LED
Open LEFT
R
o
t
a
t
e
L
i
m
i
t
T
a
b
u
n
t
i
l
L
E
D
l
i
g
h
t
s
CLOSED
LIMIT
OPEN
LIMIT
Arm in CLOSED
position
Operator
Opens RIGHT
ADJUST LIMITS:
CLOSED
LOSE
LOSE
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LIMIT
LED
lights
Limit
Tab Screw
1. Move gate to OPEN position.
2. Loosen open limit tab screw.
3. Rotate open limit tab until open
LED lights.
4. TIGHTEN open limit tab screw.
5. Move gate to CLOSED position.
6. Loosen closed limit tab screw.
7. Rotate closed limit tab until closed
LED lights.
8. TIGHTEN closed limit tab screw.
Cycle the gate OPEN and CLOSED after the limit
tabs have been set AND the arm is SECURE.
Operator will cycle slowly to LEARN the open and
closed gate positions. After the operator learns
the gate positions, it will cycle at the GATE SPEED
selected for normal operation.
Manually Release Arm
“Fine Tune” Limits Adjustment
IMPORTANT: Manually Secure Arm (see page 36)
IMPORTANT: LEDs MUST light up
when gate reaches OPEN and
CLOSE positions or operator WILL
NOT learn gate positions. If gate
positions are not learned, gate
cycling speed will remain slow
during normal operation.
IMPORTANT: DO NOT allow
positive stop on long arm to
touch short arm in closed
position. Leave about a 1/4” gap.
EXAMPLE:
LED Indicators
IMPORTANT:
Remove breather
pin from gear
reducer BEFORE
cycling operator.
WARNING: Avoid the moving arm while “Fine Tune” adjusting.
Breather Pin
CAUTI
ON
REMOVE
BEFORE
OPERA
TION
PhotoCell
Edge
UL Entrap
1
2
Limit SW
ON-LINE
MATRIX
JOG
LEFT
JOG
RIGHT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ERD
Motor
OverLoad
POWER
MC-200
Motor Controller
16
15
14
13
12
3
4
5
MAX
LED ON
Edge
Sensitivity
ERD
CAUTION
CAUTION
Make sure OPEN/CLOSE
limit rings are tightened
after adjustment or
slippage could occur.
Positive Stop
on Long Arm
Short Arm
1/4” gap
Arm in Closed Position

Table of Contents

Related product manuals