Maximum Controls Max Megatron 1400 - MATRIX 1 WIRING OVERVIEW

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETYCENTEREXIT
OPEN
MAX
GATE SPEED
STOP CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFFON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STAT US
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
Pho
toCe
l
l
Edge
UL
E
n
tr
ap
1
2
Li
mi
t SW
O
N-LINE
MA
T
R
I
X
JOG
LEFT
JOG
RI
GH
T
J
og
LT
Jog
R
T
GND
Edge 1
Edge
2
Photo
Cell
E
RD
Moto
r
Ov
erLoad
P
OWE
R
MC-20
0
Motor Cont
roll
er
1
6
1
5
1
4
1
3
1
2
3
4
5
MA
X
LE
D
O
N
Edge
Sensitivi
ty
ERD
ON/
OF
F
Bat
t
ery
E
F1/
2
Ba
t
t
er
y
Vol
t
age
Rep
lac
e
Bat
t
ery
T
E
ST
Bat
tery
Bat
tery
I
N
Error
MAX
BC-
7
Battery
M
odu
l
e
BAT
TERY
IN
PO
WER/
SO
LAR
I
N
PO
WER
I
N
Ba
t
t
e
r
y
Pa
c
k
T
O
M
O
T
O
R
CO
NTRO
LLE
R
w
ww
.
Ma
x
.
U
S.co
m
BAT
T
ER
Y
I
N
IMPO
RTANT
connect to
“BATTE
R
Y IN
b
e
fo
re use
PO
W
E
R/
SOLAR
I
N
FUSE
7
Amp
PO
WE
R
115VAC 3A max
On
Of
f
WA
RNI
N
G:
For continued
protection
agai
nst fire, replace only with the
sa
m
e
type and
ratin
g of fu
s
e.
A
V
E
RT
I
S
S
EM
E
NT
: pou
r
ne pas
co
m
p
ro
m
ettre l
a
protection contre les
ris
qu
es
d’
incendie, u
ti
li
ser un
fu
s
i
ble
de
m
êm
es type et caractéristi
qu
es
nominales
.
MOTORPower In
ALARM
BA
T
TERY
PACK
L
I
MI
T
SWITCH
MOTO
R
INPU
TS
PWR 12V
-
GND
-
-
-
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
MA
TRIX 1
Edge 1
Monitored
Reversing
Edge
Monitored
P
h
oto
Cell
OR
GND
Jog RT
Jog LT
Entrapment Protection
Inputs:
MUST jumper
unused inputs
Entrapment Protection
Sensor Guidelines
1
-
-
-
C
AUTION:
See in
st
a
l
lation
i
n
struct
io
ns.
ATTENTIO
N:
Vo
ir la notice d’i
n
st
a
llation.
Edge 2
Photo Cell
MC-2
0
0
PWR
12V
MUST be
u
sed
ONLY power entrapment protection
sensors with MC-200 PWR 12
V
In
puts
&
MUST
b
e “LEARNED”
t
o MONI
TO
R sensors.
T
o LEARN input
s
&
:
1.
MONI
TO
RE
D
Sensors
M
US
T
be
wired to
inputs
B
EF
ORE
th
ey can be
l
earned.
An
y
unus
ed inputs
MUS
T
be
jum
p
ered.
2.
Reversin
g Edge
and/or Photo
Cell can
be
w
ired
to either input
2 or 3.
3.
Press and
H
OLD the
OPEN & ST
OP
butto
ns at
th
e
same
time on Mat
rix 1
until
beep is
hear
d, l
earn mode begins
.
Learn
m
ode last
s
for
5 min.
indica
ted
by be
eping.
4.
LEDs
WILL be
ON for
each
detec
ted
s
ens
or on
M
C-200.
LE
Ds
WILL be
ON
for
BOT
H
MC-200s
when
dual
operat
ors are u
sed.
5.
Press
S
TO
P
but
t
on again
wi
thin
5 min.
to learn sensors and end
learn
m
od
e,
beeping
stops.
Input
s
ar
e now
MONI
TO
R
ED
.
2
3
2
3
2
3
A
s
ensor MUS
T
be wire
d to
EDGE
1
or
opera
t
or
WILL NOT
function.
Wire
NORMALLY
CLOSED
(N.C.
)
M
ONI
T
ORED sen
sors
ONLY
, to
e
ach
opera
t
or
’s
MC-20
0 when dual operators
are used
.
Revers
in
g Ed
g
e
and/or Ph
oto Cell c
an
be wired to
ANY
of th
e
3
Inputs
.
MC-200
PW
R 12V
MUST
be used to
power
MONITORED
sensor
s
.
UNUSED
inputs
MUS
T re
mai
n
JUMPERED
or fault will occur
.
GND
1
2
3
O
PE
NST
OP
C
LOSE
M
OTOR MOTION
MC-200 Swing
Wiring operator
turn on/off operator power
Turn AC Power
Switch ON
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
To turn OFF ALL POWER:
1. Turn OFF AC POWER Switch on MAX Megatron Toroid Box. Battery power remains ON.
2. WAIT for 15 seconds.
3. Press and HOLD (approx. 5 seconds) the RED ON/OFF BATTERY button
until MAX BC-7 LEDs turn ON, then release button. LEDs will turn OFF.
Battery power automatically turns ON.
Operator should have Input AC power wired to Toroid Box, 24V & RS-485 wired between Matrix 1 and MC-200.
TURN POWER ON. Certain LEDs should normally turn ON accordingly:
AC IN LED:
Normal - Turns ON.
Error - Not ON. Check AC power.
7 Amp Fuse blown. Replace fuse.
Input AC selector switch MUST be set to CORRECT input AC power.
POWER LED:
Normal - Turns ON.
Error - Not ON. Check POWER IN plug on bottom of MC-200.
Matrix On-Line LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Matrix 1.
Limit SW On-Line LED:
Normal - Turns ON.
Error - Not ON. Check LIMIT SWITCH plug.
BATTERY VOLTAGE LEDs:
Normal - 3 LEDs turn ON - Fully charged batteries.
Batteries need charging - LEDs will turn on in sequence until batteries are
fully charged. Batteries are NOT necessary when AC power is available.
BATTERY IN ERROR LED:
Normal - Not ON.
Error - Turns ON. Battery not plugged in to BATTERY IN port.
POWER LED:
Normal - Turns ON.
Error - Not ON. Check 24V wiring from MC-200 Primary.
Motor On-Line PRIMARY LED:
Normal - Turns ON.
Error - Not ON. Check RS-485 wiring to Primary MC-200.
Limit SW On-Line PRIMARY LED:
Normal - Turns ON.
PRIMARY GATE OPEN RIGHT OPEN LEFT LED:
Normal - Turns ON either LED according to switch setting.
Error - Not ON. Check LIMIT SWITCH plug on bottom of MC-200.
BATTERY IN USE LED:
Normal - Not ON.
Error - Flashes on and off. Battery not plugged in to BATTERY IN port on
BC-7 Battery Module.
MAX Megatron Toroid Box
MAX MC-200 Motor Controller
Matrix 1
MAX BC-7 Battery Module
1
2
3
4
DO NOT CYCLE GATE OPERATOR
AT THIS TIME
A
Located on back of box.

Table of Contents

Related product manuals