LIFT CYLINDER REPLACEMENT
CHAIN
HOIST
LIFTING
CYLINDER
COLUMN
RUNNER
ASSEMBLY
PIN
PIN
7. Lower the New Lift Cylinder
through the top of the Column.
Fasten at the top with the Pin &
Roll Pin. Then fasten at the Rod
End of the Cylinder with the Pin &
Roll Pin.
VALVE
BLOCK
CYLINDER
NUT
NUT
8. Re-connect the Nut to the Elbow on top of
the Cylinder. Re-install the Valve Cartridge,
Coil, and Coil Nut to the Hyd. Lock Valve.
Re-attach the Hyd. Lock Valve to the Column
(if needed). Re-connect the Cylinder Nut to
the Hyd. Lock Valve.
COIL
NUT
FOR UNITS SHIPPED IN EARLY 1994
9. Remove the Coil Nut from the Lock
Valve & Coil. Slide off the Coil and
unscrew the Valve Cartridge (screwed
into the Valve Block). Remove the bolts
(if any), that secure the Valve Block to
the Column. Loosen, but do not remove
the Nut on the Elbow of the Valve Block.
VALVE
BLOCK
COIL
NUT
LOCK VALVE
& COIL
NUT