RUNNER REPLACEMENT
5. Remove the Pins from the old Runner,
(two Pins on the R.H. Runner, and one Pin
on the L.H. Runner). Do not remove the
Upper Cylinder Pin at this time. Activate the
Control Switch to the “UP” position to fully
retract the Lift Cylinders.
RUNNER
PINS
6. R.H. COLUMN ONLY remove the
Switch Mounting Bracket. Remove the
terminals from the Switch and release
the electric cable from the clamp
inside the hole.
SWITCH
MOUNTING
BRACKET
CABLE
CLAMP
COVER
7. Remove the Spring Guard and
Harness in the channel of the Runner
Assembly. Remove the Hose from the
Closing Cylinder. Remove the 1” Dia.
Pin from the Rod End of the Closing
Cylinder and place the Closing
Cylinder aside.
CLOSING
CYLINDER
HOSE
SPRING
GUARD
NOTE:
If the Bed Height of the Vehicle is 54”
or more from the Ground, go to Step 9.