RUNNER REPLACEMENT
RUNNER
PINS
15. Activate the “DOWN” switch on the
Control Panel to extend the Cylinders.
Attach the Lifting Cylinder to the Runner
with the Pin and Roll Pin.
On the R.H.
Runner only, attach the fixed end of the
Closing Cylinder to the Runner with the Pin
and Roll Pin. Re-attach the Spring Guard
and Harness to the Runner.
16. Pull the electrical cables through the Switch Mounting Bracket hole and
tighten the Cable Clamp inside the Runner. Replace the wires to the switch
per the diagram below. Replace the Switch Mounting Bracket to the R.H.
Runner and re-connect the Hose to the Closing Cylinder.
17. Re-assemble the Platform to the Runners in reverse order.