Loading...
Page 13 of 36 M-21-08 REV.B
Addendum A
Remove 2 ½” of jacket portion off on the 4 wires. Cut off unused red and black wire.
Strip 3/8” of insulation off the wire and crimp ¼” female insulated quick connect to the
yellow wire. Heat shrink terminal to wire.
Strip 3/8” of insulation off the wire and crimp ¼” male insulated quick connect to the white
wire. Heat shrink terminal to wire.
3. Place 4 pcs of clip-on barrel nut onto Charge Controller as shown.
4. Install Charge Controller in Solar Box with four ¼”-20 x ¾” long bolts, ¼” washers, and ¼” lock
washers.
BOLT WITH LOCK WASHERS AND
WASHERS FROM BOTTOM OF
SOLAR BOX.
CLIP-ON BARREL NUTS
REMOVE 2 ½”
OF JACKET.
CUT UNUSED RED
AND BLACK WIRE.

Other manuals for Maxon RA-45