Page 16 of 36 M-21-08 REV.B
Addendum A
10. Route RED and BLACK wires from Optio3 WAYPOINT through cord grip in the Junction Box.
Crimp and heat shrink 3/8” ring terminals to wires and connect as shown below.
11. Route RED wire (B+) and BLACK wire (B-) from Charge Controller through cord grip in the
Junction Box. Crimp and heat shrink 3/8” ring terminals to wires and connect as shown below.
BLACK WIRE WITH 3/8” RING TO
3/8” GROUND STUD
RED WIRE WITH 3/8” RING TO
3/8” POSITIVE STUD
OPTIO3 WAYPOINT CABLE
THROUGH CORD GRIP
BLACK WIRE (B-)WITH 3/8” RING
TO 3/8” GROUND STUD
RED WIRE (B+) WITH 3/8” RING
TO 3/8” POSITIVE STUD
B+ AND B- FROM CHARGE
CONTROLLER THROUGH CORD GRIP
RED AND BLACK WIRE
FROM OPTIO3 WAYPOINT