11921 Slauson Ave.  Santa Fe Springs, CA.  90670  (800) 227-4116  FAX (888) 771-7713
34
1. See the CHECKING HYDRAULIC FLUID procedure. If necessary, add hydraulic fl uid.
2. Use voltmeter to verify the battery shows 12.6 volts or more.
3. Check for structural damage and poor lubrication. Replace worn parts.
4. Check the hydraulic cylinder. With the platform on 
the ground, remove the breather plug or vent line 
from the vent/down port of the cylinder (FIG. 34-1). 
Raise the platform even with the bed. Allow pump 
motor to run two seconds more while you watch for 
hydraulic fl uid at the vent/down port. A few drops 
of hydraulic fl uid escaping the vent/down port is 
normal; however, if it streams from the vent/down 
port, piston seals are worn. Replace seals.
5. Check fi lter in the pump reservoir. Replace fi lter if 
necessary.
6. Check for dirty pump motor relief valve. Clean if 
necessary. Replace any worn out relief valve parts.
NOTE: In most cases, you can avoid having to bleed the hydraulic system by
correctly positioning Liftgate platform before opening hydraulic lines. 
Refer to following procedure. Save time on the job and prevent accidental 
fl uid spills and hazards.
Keep dirt, water and other contaminants from entering the hydraulic system. Before 
opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydraulic lines, clean 
up contaminants that can get in the openings. Also, protect the openings from
accidental contamination during maintenance. 
CAUTION
PLATFORM RAISES PARTIALLY AND STOPS
FIG. 34-1
VENT/DOWN PORT
PRESSURE
PORT
TROUBLESHOOTING