EasyManua.ls Logo

MAYO 2000 Series - Machine Break-In

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
4.4 MACHINE BREAK-IN
Although there are no operational restrictions on
the Conveyor when used for the rst time, it is rec-
ommended that the following mechanical items be
checked:
A. When machine is received:
1. Tighten all fasteners.
2. Open breather on gearboxes by turning 1/4
turn.
3. Connect power to the unit and "bump" the
ON switch to momentarily run the machine.
Observe the direction the conveyors move.
If running in reverse, consult licensed electri-
cian to reverse direction of the motor. (If a re-
versing switch is not installed).
B. After operating for 1/2 hour:
1. Retorque all wheel bolts.
2. Retorque all other fasteners and hardware.
3. Check that all electrical connections are
tight and cords are routed out of the way or
protected.
4. Check the alignment and tension of all con-
veyor belts/chains. Realign or tighten as
required.
5. Check oil level in each speed reduction gear
box for each drive. Top up as required.
6. Lubricate all greasettings.
C. After 2, 5 and 10 hours of operation:
1. Check the alignment of all conveyor belts and
chains. Realign as required.
2. Retorque all other fasteners and hardware.
3. Check that all electrical connections are
tight and cords are routed out of the way or
protected.
4. Check the alignment and tension of all con-
veyor belts/chains. Realign or tighten as
required.
5. Check oil level in each speed reduction gear
box for each drive. Top up as required.
6. Then go to the regular servicing and mainte-
nance schedule as dened in the Maintenance
Section.
FIG. 3 TIGHTEN
FIG. 4 BREATHER (TYPICAL)