II. Testing the Dolphin
Step 3. Replace motor unit
When re-inserting the
cable into the motor
unit, make sure you
use a screw driver to
push the triangular
piece all the way to the
bottom to ensure
connectivity.
connectivity.
13
Make sure that when
re-securing the cable
you leave enough slack
so that it touches the
plastic net. This
ensures it will not be
damaged by the
spinning impeller.