5.12 Interval function (batch processing)
The interval function sections the folding operation at each set time.
Select the interval function in the operation of “5.8 Functions that can be set.”
Method of switching the screen
The screen switches by pressing the “1000” key.
(Setting check Sheet count setting Waiting time setting
Setting check ・・・)
[Sheet count setting]
Enter the number of sheets to be folded in succession (sheet count).
Up to 500 sheets of paper can be set.
[Waiting time setting]
Enter the waiting time (seconds) after successive folding.
Up to 20 seconds can be set.
[Setting Check]
Before starting the folding operation, check the sheet count and waiting time settings
on this screen.
* To cancel the interval, flicker “i” by pressing the “MODE” and
“1000” keys together.