Adjustment
19
Verifying Door Operation
Whenever power is turned on (cycled) to the SmarTraq drive, the first open operation will be at
Low Speed.
To verify door operation:
1. Hold Open/Close in Open position. Doors will open and detect Full Open position. DOL
should be displayed.
2. Hold Open/Close in Close position. Doors will close and detect Full Close position. DCL
should be displayed.
Door Operation Example
When in Local mode, you can operate the doors using the programmer switches.
To open the doors:
• Hold the Open/Close switch to Open. Pause at any point if desired. The Limit 2 LED will
light at some (user adjustable, LC parameter) point as the doors are opening. When the
Door Open Limit is reached (DOL relay energized), the DOL LED will light.
To close the doors:
• Hold the Open/Close switch to Close. Pause at any point if desired. The Limit 1 LED will
light at some (user adjustable, LP parameter) point as the doors are closing. When the
Door Close Limit is reached (DCL relay energized), the DCL LED will light.
To close at nudging speed:
• Hold the Open/Close switch to Close. Press the Nudge button. The doors will close at
reduced speed.