DC5xD MK3 GENSET CONTROLLER USER MANUAL
7
Low oil pressure
High temperature
Low fuel level
External emergency alarm
D+ open
RPM Lost
Sensor Open
Over Frequency
Under Frequency
Over voltage
Under voltage
Over current
Non-balance of current
Over power
Maintenance expire
Low water level alarm
Emergency Stop
Crank failure
Battery over voltage
Battery under voltage
The charger fails to charge
Charger charging failure
Stop Failure
5. Parameters
Options
Parameters
Working voltage
DC8V----36V Continuous
Power consumption
Standby:24V:MAX 1W
Working:24V:MAX5W
AC Voltage Input
1P2W 30VAC-276VAC (ph-N)
2P3W 30VAC-276VAC (ph-N)
3P4W 30VAC-276VAC (ph-N)
Rotate speed sensor
Frequency
50-10000Hz
MAX Accumulating Time
99999.9Hours(Min Store time:6min)
Fuel Relay Output
Max 16Amp DC+VE Supply voltage
Start Relay Output
Max 16Amp DC+VE Supply voltage
AUX. OUTPUT 1
Max 16Amp DC+VE Supply voltage
AUX. OUTPUT 2
Max 16Amp DC+VE Supply voltage