Page 106 Speed Level Series - Service & Parts Manual
January 2019Section 8 - Troubleshooting - 3084RT Models
be allowed again when the heatsink cools to below 70ºc.
The heatsink temperature can be viewed in the DIAGNOSTICS/SYSTEM/ TEMPERATURE
display, ID # 2a5.
The heatsink must be bolted to a significant metal panel of the vehicle, capable of dissipating
heat to the environment.
UNCALIBRATED
The height and/or pressure sensors have not been calibrated see CALIBRATION OF
OVERLOAD SYSTEM (CE option only).
If machine is not equipped with Overload system, refer to SETUPS table and change those
personalities that do not match the figure listed in the table.
EXTERNAL ALL, EXTERNAL DRIVE, EXTERNAL LIFT
An external cutout input is preventing functions – determine the cause of the external cutout (for
example, a limit switch)