Page 113 Speed Level Series - Service & Parts Manual
January 2019Section 8 - Troubleshooting - 3084RT Models
Other Messages
The following are other HELP messages:
SOME BIG BAD PROBLEM! ______________________________ Flash Code: 9/9
This message should not occur!
FACTORY OVERRIDE___________________________ Flash Code: (fast flashing)
When the controller is first shipped, prior to initial calibration, it is configured in a special “factory
override” state. In this state, none of the normal shutdowns or interlocks will occur – the vehicle
can be freely lifted/lowered and driven irrespective of any calibration needs, vehicle tilt, etc.
As soon as an EZ-Cal is connected to the controller, the factory override state is ended.
If calibration does not occur, then the factory override state will recur if the EZ-Cal is
disconnected and power is switched off/on.
Important: Never use a vehicle in factory override; this state is ONLY intended for use during
manufacture! While factory override is active, the LED is rapidly flashed on/off.