Part # 43443
February 2019
Operators Manual
3369ERT Serial Number Range 13200000 - Up
3369RT Serial Number Range 13300000 - Up
4069ERT Serial Number Range 13700000 - Up
4069RT Serial Number Range 13800000 - Up
69 Series
ART_4265
RT - Internal Combustion
ERT - Electric

Questions and Answers

  • T
    Thomas WelchAug 21, 2025
    What to do if Platform ECU Fault occurs in Mec Scissor Lifts?
    • C
      Cassandra ScottAug 22, 2025
      If you're encountering a Platform ECU Fault on your Mec Scissor Lifts, it could be due to an ECU/Platform Communication Fault. Begin by inspecting the communication cable connections and all related wiring. If the issue persists, consider replacing either the PCU or ECU.
  • T
    Thomas LopezSep 4, 2025
    Why does Chassis Choke Sw Fault occur on Mec Scissor Lifts?
    • K
      Kevin MorganSep 4, 2025
      This is a self-check fault. Make sure not to press any other button during power-on of your Mec Scissor Lifts.
  • S
    Sarah GraySep 2, 2025
    What to do if Platform Start Sw Fault appears on Mec 69 Series Scissor Lifts?
    • R
      Rhonda DanielsSep 3, 2025
      This is a self-check fault. Don’t touch any other button when powering on your Mec Scissor Lifts.
  • J
    John CherrySep 1, 2025
    What causes Chassis Start Sw Fault in Mec 69 Series?
    • V
      Victor RandolphSep 1, 2025
      This is a self-check fault. Avoid pressing any other buttons when powering on your Mec Scissor Lifts.
  • E
    evansdakotaAug 30, 2025
    What should I do if Mec 69 Series Scissor Lifts show Floating Coil Right Fault?
    • R
      Roger LewisAug 31, 2025
      To address a Floating Coil Right Fault on your Mec Scissor Lifts, first, verify that all connections to the coil’s terminals are properly tightened. If the connections are secure, examine the coil to determine if it is open or shorted.
  • G
    Gregory WoodardAug 29, 2025
    How to troubleshoot Floating Coil Left Fault on Mec 69 Series?
    • C
      Cindy DawsonAug 29, 2025
      If you're experiencing a Floating Coil Left Fault on your Mec Scissor Lifts, start by checking the connections to the coil’s terminals, ensuring they are secure. If the connections are tight, inspect the coil itself for any signs of being open or shorted.
  • G
    gwhiteAug 27, 2025
    What causes Off Neutral Drive Joystick error in Mec 69 Series?
    • J
      jonathanhartAug 27, 2025
      This is a self-check fault. Make sure you are not touching the joystick or any other button when powering on your Mec Scissor Lifts.
  • S
    stevenbrownAug 26, 2025
    How to resolve Internal ECU Fault in Mec 69 Series?
    • T
      theresacookAug 27, 2025
      If you have an Internal ECU Fault with your Mec Scissor Lifts, replace the ECU.
  • D
    daviserinAug 25, 2025
    What to do for Pressure Sensor Fault in Mec 69 Series?
    • R
      Robert ReyesAug 25, 2025
      If a Pressure Sensor Fault arises in your Mec Scissor Lifts, you can try the following: Initially, restart the system. Then, carefully examine the sensor's wiring. If the problem persists, attempt to reset the sensor. If none of these steps work, consider replacing the sensor.
  • M
    Melissa FlynnAug 23, 2025
    How to fix Angle Sensor Fault in Mec 69 Series Scissor Lifts?
    • S
      Sonya DunlapAug 23, 2025
      If you're facing an Angle Sensor Fault with your Mec Scissor Lifts, try these steps: First, restart the system. Next, carefully inspect the wiring associated with the sensor. If the problem continues, attempt to reset the sensor. As a last resort, replace the sensor.