5
TROUBLE SHOOTING
CODES
SOLUTIONPROBLEM
HI BAT
<10V
Check battery connection. Replace
battery if it continues.
LO BAT
>15V
Replace with a charged battery.
OFFbat
The system discovered that the
battery was out of range for more
than 3 seconds
Reconnect the battery.
OVERLd
After 3 consecutive FAULT1
recover attempts (after letting the
smart driver to cool down before
the next attempt.)
Disconnect power, wait 5 seconds
or longer and then reconnect.
OUETHt
After 3 consecutive FAULT1
recover attempts (no smart
FET’s cool down before the next
attempt.)
Disconnect power, wait 5 seconds
or longer and then reconnect.
FAULT9
Run-Away motor - Limit switch
remains un-cocked for more than
4 seconds.
Disconnect power, wait 5 seconds
or longer and then reconnect.
FAULT8
Open load detected.
Disconnect power, wait 5 seconds
or longer and then reconnect.
If the display reads unsafe/loaded, but is in the disarm position with the toggle switch armed,
the limit switch is stuck in the closed position and will need to be xed or replaced.
ADDITIONAL TROUBLE SHOOTING TIPS
TEST or SU1
Water or condensation causeing
corrosion and unwanted shorts
on the Arm/Disarm switch.
Verify or Replace the Arm/Disarm
switch.