1-3
End to End synchronous current measurement with
Graaf method using the DC interference voltages for fault location
The measurement of parameters like:
Loop resistance
Resistance difference
Insulation resistance
KMK 8 provides remote control for far end devices like:
KLC 8 loop closing device to close or open the loop during the
measurement (e.g fault location with Küpfmüller method).
KMK 80S slave unit to measure the current at the far end in case
of fault location with Graaf method

Table of Contents