Do you have a question about the Megger MIT400 Series and is the answer not in the manual?
Continuity Test Current | 200 mA |
---|---|
Safety Rating | CAT IV 600 V |
Insulation Resistance Test Voltages | 50V, 100V, 250V, 500V, 1000V |
Voltage Range | 0V to 600V AC/DC |
Battery Type | 6 x AA batteries |
Safety Standards | IEC61010 |
Accuracy | ±3% ±2 digits |
Lists the items included in the instrument's case.
Details the standard accessories and components supplied with the instrument.
Information on battery installation and replacement for the instrument.
Procedure to verify the condition and functionality of test leads before use.
Crucial safety advice regarding voltage limits and hazardous conditions.
Description of the main features and controls of the MIT430 instrument.
Detailed explanation of the instrument's Liquid Crystal Display (LCD) and its indicators.
Information about voltage warnings and automatic inhibition of tests.
Instructions on how to use and manage the instrument's backlight.
Guidance on connecting standard test leads to the instrument's sockets.
Instructions for using the SP5 switched probe for hands-free testing.
Explanation of True Root Mean Square (TRMS) measurement behavior.
Crucial safety warnings specific to high-voltage insulation resistance testing.
Explanation of the automatic discharge feature after insulation tests.
Step-by-step guide for performing standard insulation resistance tests.
Explanation of the standard count down timer function for timed tests.
Definition and calculation of the Polarization Index (PI) test.
Definition and calculation of the Dielectric Absorption Ratio (DAR) test.
Warning about pressing the PI/DAR/t button which may alter test modes.
Step-by-step guide for performing capacitance measurements.
How capacitance is used to measure cable distance on specific models.
Details on various setup options for configuring instrument settings and thresholds.
Step-by-step guide on how to navigate and change instrument setup parameters.
Procedure for storing measurement results in the instrument's memory.
Instructions for retrieving previously stored test results.
How to recall and view PI and DAR test results.
Steps to recall PI or DAR measurement results from memory.
Step-by-step guide to delete individual test results.
Step-by-step guide to delete all stored test results.
Guide to setting up Bluetooth communication between the instrument and PC.
Steps to pair the instrument with a computer via Bluetooth.
Steps for performing standard data downloads after initial setup.
How to check battery status and replace the batteries.
Explanation of the blown fuse indicator and its meaning.
Technical details and accuracy for insulation resistance measurements.
Technical details for continuity and resistance measurements.
Technical details for voltage and capacitance measurements.
Fuse requirements and rating for replacement.
Instrument's safety compliance and application definition.
Operating conditions, humidity, temperature effects, and altitude.
Instrument inaccuracy under ideal and real-world conditions.
Lists the standard accessories that come with the instrument.
Lists accessories specific to the MIT430 and MIT485 models.
Lists optional accessories and replacement parts available for purchase.
Warning that unauthorized repairs void the instrument's warranty.
Information on obtaining calibration, repair services, and spare parts.
Procedure for returning the instrument for service or recalibration.