Important safety precautions and warnings for using the instrument.
Procedure for measuring AC and DC voltage using 2-terminal connections.
Critical safety precautions for performing insulation resistance tests.
Step-by-step guide for performing insulation resistance tests on 2-terminal instruments.
Procedure for performing Dielectric Absorption Ratio (DAR) measurements.
Procedure for measuring insulation resistance with 2-terminal instruments.
Using variable test voltages for insulation testing on specific instrument models.
Performing automatic PI and DAR tests for insulation analysis.
Procedure for performing continuity tests using 2-terminal instruments.
Procedure for saving test results to the instrument's memory.
How to recall stored test results from the instrument's memory.
Step-by-step guide for pairing the MIT instrument with a PC via Bluetooth.
Instructions for initiating and completing data download from the instrument to a PC.
Preparing the instrument and PC for downloading test results via Bluetooth.
Guide to navigating and changing configuration options within the instrument's SETUP menu.
Technical specifications related to insulation testing, including voltage and accuracy.
Technical specifications related to continuity testing, including range and accuracy.
Understanding the battery indicator and procedure for replacing batteries.
Step-by-step instructions for safely replacing the instrument's batteries.
Step-by-step instructions for safely replacing fuses in the instrument.
Information on warranty coverage, repair procedures, and conditions for the instrument.
Important safety precautions and warnings for using the instrument.
Procedure for measuring AC and DC voltage using 2-terminal connections.
Critical safety precautions for performing insulation resistance tests.
Step-by-step guide for performing insulation resistance tests on 2-terminal instruments.
Procedure for performing Dielectric Absorption Ratio (DAR) measurements.
Procedure for measuring insulation resistance with 2-terminal instruments.
Using variable test voltages for insulation testing on specific instrument models.
Performing automatic PI and DAR tests for insulation analysis.
Procedure for performing continuity tests using 2-terminal instruments.
Procedure for saving test results to the instrument's memory.
How to recall stored test results from the instrument's memory.
Step-by-step guide for pairing the MIT instrument with a PC via Bluetooth.
Instructions for initiating and completing data download from the instrument to a PC.
Preparing the instrument and PC for downloading test results via Bluetooth.
Guide to navigating and changing configuration options within the instrument's SETUP menu.
Technical specifications related to insulation testing, including voltage and accuracy.
Technical specifications related to continuity testing, including range and accuracy.
Understanding the battery indicator and procedure for replacing batteries.
Step-by-step instructions for safely replacing the instrument's batteries.
Step-by-step instructions for safely replacing fuses in the instrument.
Information on warranty coverage, repair procedures, and conditions for the instrument.
| Test Voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
|---|---|
| Safety Category | CAT IV 600 V |
| Short Circuit Current | 200 mA |
| IP Rating | IP54 |
| Accuracy | ±2% ±2 digits |
| Display | Digital and Analog |
| Battery Type | 6 x AA (IEC LR6) |
| Continuity Range | 0.01 Ω to 100 Ω |
| Voltage Range | 0 to 600 V AC/DC |