EasyManua.ls Logo

Megger Programma Sverker 750 - User Manual

Megger Programma Sverker 750
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SVERKER
750/760
User's manual
Relay Test Unit

Table of Contents

Questions and Answers

  • A
    Amanda RamirezAug 19, 2025
    How to fix no output current from Megger Programma Sverker 750 Test Equipment Sverker?
    • C
      colin56Aug 19, 2025
      If there's no output current from your Sverker, here's what you should check: * Make sure the power cord is properly plugged in. * Check miniature circuit breakers F1 and F2, as they may have tripped. * The thermal cut-out may have tripped due to an overload. This resets automatically after some time.
  • J
    Jeffrey LeeAug 22, 2025
    What to do if Megger Test Equipment displays abnormal current readings?
    • J
      Jennifer FloresAug 22, 2025
      If you are seeing abnormal current readings on your Megger Test Equipment, it's likely that the current is being measured at the wrong test point. Ensure that you have selected the correct test point for the ammeter.
  • S
    sandovalamandaAug 23, 2025
    What does O.F. mean on Megger Programma Sverker 750?
    • K
      Kyle StoneAug 23, 2025
      O.F. means overflow and indicates that the range being used has been exceeded. One possible cause is that the measurement cycle proceeded too rapidly to permit the range to be switched automatically. You should repeat the measurement. Since range switching data is stored in a memory, your second try may very well be successful.
  • R
    reyestravisAug 26, 2025
    What to do if no current reading appears on Megger Programma Sverker 750 Test Equipment?
    • M
      Melissa KaufmanAug 26, 2025
      If no current reading appears when measurements are made via the ammeter’s panel input, the miniature circuit breaker F4 may have tripped because the measured current exceeded 6 A. Check the miniature circuit breaker.
  • D
    davismelissaAug 28, 2025
    How to fix no voltage reading on Megger Programma Sverker 750?
    • W
      Wyatt MurphyAug 28, 2025
      If no voltage reading appears, the voltmeter panel input is not connected. Connect the voltmeter input.
  • K
    Kathy RichAug 30, 2025
    Why is there no phase-angle reading or jumping values on my Megger Programma Sverker 750?
    • D
      David BrownAug 30, 2025
      If you're getting no phase-angle reading or jumping values, it means no current is being generated. Both current and voltage must be generated. Press 'ON' to generate the current.
  • S
    Sabrina OdonnellAug 31, 2025
    Why are operating times unexpectedly short on Megger Programma Sverker 750?
    • J
      John CooperAug 31, 2025
      If you are seeing unexpectedly short operating times, it's because contact bounces are occurring in the protective relay equipment. To resolve this, connect the Sverker capacitor in parallel with the test object.
  • J
    Joseph SmithSep 3, 2025
    What causes make/break contact malfunctions in Megger Programma Sverker 750?
    • P
      petersmatthewSep 3, 2025
      If the make/break contact malfunctions, the miniature circuit breaker F3 may have tripped. Check the miniature circuit breaker.
  • M
    murraychristopherSep 5, 2025
    Why does Megger Programma Sverker 750 show fewer reclosings than desired?
    • M
      Matthew BurnsSep 5, 2025
      If fewer than the desired number of times appear in the time table after measuring reclosings, the 'delay off' function is activated (time that elapses after tripping before generation is stopped) and start and stop pulses are issued during the 'delay off' period. Shorten the 'delay off' period or set it to 0.
  • L
    Leonard BlankenshipSep 6, 2025
    What causes the separate AC voltage source to malfunction on Megger Programma Sverker 750 Test Equipment?
    • E
      Eric HernandezSep 6, 2025
      The PTC resistor that serves as a thermal cut-out may have tripped because of an overload. Wait. This cut-out is reset automatically after a certain amount of time has elapsed.

Megger Programma Sverker 750 Specifications

General IconGeneral
Frequency Range15 - 500 Hz
Communication InterfaceUSB, Ethernet
Power Supply100-240 V AC, 50/60 Hz
Voltage Output Range0-300 V AC/DC
Current Output Range0 to 30 A
Phase ConfigurationSingle-phase
Accuracy0.1% of setting
DisplayLCD

Related product manuals