5.6.2 Programs Setting
Program
Parameters
Range
Unit
Factory
Volume
Explanation
Hardness
Target
hardness
1~12
==
8
Higher volume results in harder product.
Default
speed
Low/High
==
Low
Low: Low-speed agitation.
High: High-speed agitation.
Overrun
On/Off
==
On
The machine will automatically switch to
high-speed when the product temperature
is in the range of 1 °C ~ -3 °C.
Time
Time setting
2~35
minutes
10
Freezing time.
Default
speed
Low/High
==
Low
Low: Low-speed agitation.
High: High-speed agitation.
Temperature
Target
temperature
-15 ~ 2
°C
-8
Target temperature.
Default
speed
Low/High
==
Low
Low: Low-speed agitation.
High: High-speed agitation.