2. Remove the tab holder (1) with a quarter turn coun-
terclockwise.
000031
1 2
Fig. 41: Cleaning tablet
3. Insert a cleaning tablet (1) into the tab holder.
4. Turn the tab holder a quarter turn clockwise firmly
back into the machine (2).
5. Close the machine door.
6. Use the "Cleaning tablet is inserted" button to
confirm that a cleaning tablet has been inserted.
͵ The machine starts the automatic cleaning pro-
cess.
͵ The cleaning process takes a few minutes.
The machine is then switched off or depending on the
selection, it goes back to operational readiness mode.
Final activities
1. Clean the dispensing area once the automatic
cleaning process is complete (see chapter 8.10 on
page 34).
2. If you want to continue using the machine, refill the
milk as described in chapter 5.3.3 on page 12.
9 The milk and brewing system has been cleaned.
8�6�3 Cleaning the instant system
000148
2
1
Fig. 42: Opening the instant container cover
1. Open the machine door using the key (2).
2. Lift the instant container cover (1) upwards carefully.
3. Carry out the steps as described below.
There will be one or two instant containers depending on
the equipment.
Removing the mixer unit
000174
1
12
3
4
5
6
Fig. 43: Mixer unit
1. Turn the powder chute (2) upwards so that no
powder can fall out.
2. Remove the instant container (1).
Cleaning