OPERATION
33
Problem Horn
Monitor
Display
Guardian
Activated
Engine
Power
Reduced By
Crankshaft
Sensor Problem
Steady Horn Yes Yes 70%
Cam Sensor
5 Beeps‑3 Sec.
Long
Yes Yes 70%
MAP Sensor Error
5 Beeps‑3 Sec.
Long
Yes No
RPM limit to
5150
Fuel Pressure
Sensor Failure
3 Beeps‑1.5
Sec. Long
Yes No
Block Pressure
Sensor Failure
3 Beeps‑1.5
Sec. Long
Yes No
Charge
Temperature
Sensor Failure
3 Beeps‑1.5
Sec. Long
Yes Yes 70%
CAN Bus Problem
3 Beeps‑1.5
Sec. Long
Yes Yes
70% or
Forced Idle
Coolant
Temperature
Sensor
3 Beeps‑1.5
Sec. Long
Yes No
Throttle Position
Sensor
3 Beeps‑1.5
Sec. Long
Yes Yes 70%
Electrical System Overload Protection
If an electrical overload occurs, a fuse or circuit breaker opens. Locate
and correct the problem before replacing the fuse or resetting circuit
breaker.
A circuit breaker protects the engine wiring harness and
instrumentation power lead. Reset by pushing the reset button.
Four fuses are located at the upper rear of the engine containing 5
and 15 amp fuses.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury Racing HP850 SCi and is the answer not in the manual?

Mercury Racing HP850 SCi Specifications

General IconGeneral
BrandMercury Racing
ModelHP850 SCi
CategoryEngine
LanguageEnglish

Related product manuals