INSTALLATION
Page 1D-26 90-888438 JUNE 2002
4. Snap flush adapter into bracket as shown.
a
b
a-Bracket
b-Flush Adapter
Operation Instructions
WARNING
DO NOT run engine on flushing kit above idle speeds. Damage to engine from over-
heating, due to lack of water supply may occur.
1. With engine off, remove flush adapter plug and attach water hose.
52121
a
b
a-Flush Adapter
b-Water Hose
2. Turn water hose on and flush engine block for a minimum of ten minutes.
3. Remove water hose from flush adapter and install adapter plug. Tighten plug securely.
Place flush adapter into adapter bracket.