XBW Sole Only 16
Cut Sheet/Specifications
XBW Sole Only
Specifications subject to change without notice.
Dimensions: 34” wide (without soap tray)
(See Drawing Next Page) 46.1” wide (with side mount soap tray)
82.1” long (including steps)
46.7” high (with 8 adjustable leveling feet)
Weight: 600 lbs.
Shipping Weight: 900 lbs.
Cycle Activation: Photoeye’s at each entrance and exit of the system.
Cycle Length: 8 Seconds (factory setting) Cycle Length Adjustable
Water Inlet: ¾” male garden hose fitting, maximum temperature 110°F
Water Supply Line: 3/8” ID line minimum - 4 GPM Minimum at 50 PSI Max.
Water Consumption: 2.6 GPM at 50 PSI
Electrical: 120-volt, single phase, 20 amps/NEMA 5-20 Power Cord
Drain: 2male pipe thread in catch basin - to floor drain. (Floor drain required)
Warnings/Cautions:
Do not hard pipe to the plumbing inlet as this will prevent future serviceability.
Use a flexible water connection to the system.
Always install facility water shut off valve near the system.
Do not hardwire the systems electrical power cord without having a way to disconnect the system
from electrical source for future serviceability of the system.
Always lockout & tag out when servicing the system or cleaning.
This equipment contains moving parts and starts automatically. DO NOT USE with loose clothing
that can be caught in the system. This includes, but is not limited to, long smocks, frock ties,
shoelaces and street shoes.
Use in Wet environments as there is water tracking from use of the system.
Do not reduce or restrict the drain outlet.
Make certain system is pitched towards drain.
System has 3 overflow drains should main drain become clogged.
System is not intended to be used with a macerator pump directly connected to the system drain.
Consult local and national codes: conformity and compliance to local and national codes is the responsibility
of the installer.