Page 5 MD Series Ovens 32Z3329 Issue 6
Installation instructions
Power Supply Requirements
The oven should be connected to a suitable electricity supply, which can cope with the switching-
on surge that occurs with certain types of catering equipment, such as microwaves. Because of
this requirement, we strongly recommend that a separate, suitably rated supply is installed for the
oven.
The supply for the oven should be fitted with a Type "C" circuit breaker, rated at 16A.
In order to maintain adequate ventilation for air intake and exhaust, and to allow access for
cleaning filters, you must allow a minimum of 50mm clearance all around the oven. Air intake
temperature should not exceed 35°C - excessive temperature can lead to reduced operating duty
cycle or premature ageing of internal components.
Positioning the Oven
maximum
3 ovens
in a stack
ALWAYS Place containers in the cavity carefully - impact damage may chip the oven shelf
NEVER Install an oven above fryers, grills, griddles or any other major heat source
NEVER Stack machines on top of each other without using the stacking adapter provided
stacking adapter