MFJ-495 Memory Keyer Instruction Manual
© 2001-2009 MFJ Enterprises, Inc. 41
Appendices
Resetting the Keyer
Each time the keyer is turned off, the microprocessor powers down and saves all memories and
configurations to non-volatile memory ready to be used the next time the unit is turned on again. If the
keyer in not working properly, even on initial power on, try resetting to the factory defaults.
Factory Defaults
The unit is shipped with the following default settings for all users 1 to 4:
Main Menu [1A][2A][3A][4A]
Setup Menu Speed Ratio
Memory Bank A
Speed Control Range 13 to 39 WPM
Speed Ratio 3-to-1
Overall Speed 13 WPM
Farnsworth off
Weight 50% constant
Character Space 3 units
Word Space 7 units
Keying Compensation 0 msec
Keying Delay 0 msec
PTT Hang Time 1000 msec
Tone Frequency 701 Hz
Serial Number 0001
Leading Zeroes on and send as O (dah-dah-dah)
Other Zeroes send as 0 (dah-dah-dah-dah-dah)
Nines send as 9 (dah-dah-dah-dah-dit)
Iambic Mode A
Reverse Mode off (dot to tip, dash to ring)
Paddle Mode automatic
Monitor Mode on
Output Mode on
Queue Mode on
Pulse Tune Speed 75 WPM
Pulse Tune Weight 13% duty cycle
Quick Speeds 13, 15, 18 and 20 WPM
To reset the keyer to these defaults:
1. Skip to step 6 if you want to reset the current user; otherwise continue with step 2.
2. Turn on the power to the keyer.
3. Press and hold the Menu button for two seconds to go to the setup menus.
4. Press Previous or Next button to go to the User menu.
5. Press Up or Down button to select the user to be reset to factory defaults.
6. Turn off the power to the keyer.
7. Press and hold both the Menu and F2 buttons while turning the power on.
8. Release the buttons when DEFAULTS RESET appears on the display.