guard to see if it is closed when set against G.S. coupling, Figure 12, and
open when coupling is disengaged, Figure 12.
3.2 Lubrication
3.2.1 Lubrication Bearings
The pillow block and conveyor bearings should be lubricated every 100
hours of operation. See Figure 9 for location of grease fittings. Grease
vent holes located behind pillow block housing and in gearbox cover
nearest the bowl, are shown in Figure 9. Proper greasing is obtained when
excess grease comes out the vent holes.
The following is a list of factory approved greases which may be used for
bearing lubrication.
Mystick JT-6 Synthetic Blend
Nils Lithoplex
NOTE: Use only factory approved lubricants. Use of non-approved
lubricants will void warranty.
15