Overspeed Alarm
Setting
SPEED,A,B,M#
SPEED,OFF# CANCEL OVERSPEED ALARM OK
Functions
Command Format
Explanation
Alarm Commands
Example: SPEED,ON,120,1# ( Means the speed limit is
120km/h and the alarm way is via SMS and Server )
A=ON/OFF, open or close over speed alarm, defaultOFF
B=1255(km/h), speed limit, default100(km/h);
M=0/1/2, way of alarm, 0 : SERVER only, 1: SERVER+SMS,
2: SERVER+SMS+CALL; default: 1
Heartbeat
Packet Upload
HBT,time#
Example: HBT,3# ( Means the tracker will send hearbeat
data package to server very 3min to keep the network
connected )
Time: 1-60min, default 3min
Example:
FENCE,1,500,22.65897,114.985231# ( Means set
up the fence 1 as center dot 22.65897,114.985231,
radius 500m )
FENCE,2,300,,# ( Means set up the fence 2 with the
center dot as the last GPS fixed position, radius:
300m)
S=14, fence serial number
R=100-65535m, Radius value
LNG=Longtidue of the center dot
LAT=Latitude of the center dot
NOTE: 1. Fence only can be setup when the device
has GPS signal, if no GPS signal, then reply:
Unable to set GEO fence now, please fix the GPS
location firstly!
2. User can set with or without coordinates in the
command, if without coordinates then it will set up as
the last GPS fixed position
ID: 19172012644 (Device ID number)
FENCE1: 500m(Radius),
22.65897,114.985231(center coordinate)
FENCE2: 300m(Radius),
22.65897,114.985231(center coordinate)
FENCE3: 400m(Radius),
22.65897,114.985231(center coordinate)
FENCE4: 400m(Radius),
22.65897,114.985231(center coordinate)
Working Mode Setting MODE,A,T1,T2#
A=1/2/3, 1 Realtime tracking mode 2 Regular
reporting mode 3: Power saving mode; Default mode: 1
A=1 (For example: MODE,1,10,3600# means the tracker
will work under mode 1, it will upload every 10s under
moving status and 3600s under static status)
T1upload interval of GPS data in moving status,unit:
second,10-3600s; default: 10s
T2upload interval of GPS data in static status, unit:
second, 180-86400s; default: 3600s
NOTE: Device sends data to server according to the time
interval and always stays online.
User needs to set reporting time to server when moving
and when no moving. GPS/WIFI on when moving and off
when not moving.
A=2 (For example: MODE,2,0800,1# means the tracker
will work with mode 2 since the next 08:00am, and upload
every 1 hour )
T1: interval start time,format: HHMM
T2: time interval,range: 1-72 unit: hour,default interval:
24hours
Note: Under Mode 2 the device will disconnect with server
after reporting, but it still can receive SMS and Call.
A=3 (For example: MODE,3# )
NOTE: Under mode 3, no need set reporting time interval,
the device will always keep connect with server with the
heartbeat data.
Device only sends data to server when an alarm occurs.
GPS/WIFI only triggers when there is an event. (the rest of
the time, GPS is off)
Example:
DFENCE,1# (Means delete the fence 1)
DFENCE,0# (Means delete all fence)
S=04, fence serial number
Example: SEARCH#
Note: 1. After received this command, device will
start live tracking every 10 seconds and last for 10
minutes.
2. When there is an Geo-fence alarm, this search
mode will be activated automatically
Example: BEEP,ON#
BEEP,OFF#
Example: CENTER,A,+8613800138000#
Note: Please set up the center number with the
country code as prefix!