6. Functions Explanation
* SMS command format: MODE,A,T1,T2#
a. Working Modes Setting
For example:
MODE,1,10,3600#
SET MODE OK
MP50G
For example:
MODE,3#
SET MODE OK
MP50G
For example:
MODE,2,0800,1#
SET MODE OK
MP50G
T1upload interval of GPS data in moving status,unit: second,10-3600s;
default: 10s
T2upload interval of GPS data in static status, unit: second, 180-86400s;
default: 3600s
NOTE:
1. Device sends data to server according to the time interval and always stays online.
2. User needs to set reporting time to server when moving and when no moving.
GPS/WIFI on when moving and off when not moving.
NOTE:
Under Mode 2 the device will disconnect with server after reporting, but it still can
receive SMS and Call.
A=3 (For example: MODE,3# )
NOTE:
1. Under mode 3, no need set reporting time interval, the device will always keep
connect with server with the heartbeat data.
Device only sends data to server when an alarm occurs.
2. GPS/WiFi only triggers when there is an event. (the rest of the time, GPS is off)
A=2 (For example: MODE,2,0800,1# means the tracker
will work with mode 2 since the 08:00am, and upload
every 1 hour )
T1: interval start time,format: HHMM
T2: time interval,range: 1-72 unit: hour,default
interval: 24hours
A=1 (For example: MODE,1,10,3600# means the tracker will work under mode 1, it
will upload every 10s under moving status and 3600s under static status)
A=1/2/3, 1 Realtime tracking mode 2 Regular
reporting mode 3: Power saving mode; Default mode: 1