Add SOS
Administrator Number
SOS,A,1st number,2nd number,
3rd number#
Example:
Set 3 numbers at a time:
SOS,A,13800138000,13800138001,13800138002#
Set the first numberseparately:
SOS,A,13800138000#
Set the second number separately:
SOS,A,,13800138001#
Means to set 3rd number separately:
SOS,A,,,13800138002#
Delete SOS
Administrator Number
Add Center Number
Delete Center Number
Data Upload
Time Interval
Heartbeat Packet
Upload
Sensor Sensitivity
Arm manually ARM#
SOS,D,1st number,2nd number,
3rd number# or SOS,D,1,2,3#
CENTER,A,center number#
CENTER,D#
TIMER,T1,T2#
HBT,time#
LEVEL,A#
Example:
Directly delete the number:
SOS,D,13800138000#
Delete 1st number:
SOS,D,1#
Delete 2nd number:
SOS,D,2#
Delete the 2nd and 3rd number:
SOS,D,2,3#
DEL CENTER OK
Set the device into arm mode
Disarm manually DISARM# Set the device out of arm mode
Example: CENTER,A,008613800138000# (Means
the tracker will just can be controlled by this number
008613800138000, 0086 is country code)
NOTE:
1. Please set up the center number with the country
code as prefix!
2. After set up center number, the tracker will just can
be controlled by center number, it will not reply
commands from other numbers!
Example: HBT,3# (Means the tracker will send
heartbeat data package to server every 3 min for
connection maintenance)
NOTE: Range :1-60min, default 3min.
Example: LEVEL,2# (Means set up the shake
sensor level to 2)
NOTE: A:Sensitivity Level 1-9 (1-9 is from week
to strong vibration)
Example: TIMER,5,180# (Means the tracker will
upload data every 5s when ACC is on and 180s
when ACC is off)
T1 ranges 0/5~18000 or 0(seconds), upload interval
when ACC ON, 0 means no upload, default is 10;
T2 ranges 0/5~18000 (seconds), upload interval
when ACC OFF, default is 10;