MicroLab
Operating Manual
Federal (USA) law restricts this device to sale by or on
the order of a physician or licensed practitioner.
MAN1300
085-73
Issue 1.6
February 2019
Micro Direct, Inc.
803 Webster Street
Lewiston, ME 04240
1-800-588-3381
www.mdspiro.com
Mail In Yellow Warranty Card
Receive 25 PFT Filters
FREE!!

Questions and Answers

  • S
    Stephanie BassAug 14, 2025
    Why doesn't my Micro Direct MicroLab Medical Equipment battery hold a charge?
    • E
      Eddie TaylorAug 14, 2025
      There are a couple of reasons why the battery in your Micro Direct Medical Equipment might not be holding a charge. It could be due to an exhausted battery, in which case you should replace the battery or return the unit for servicing. Alternatively, there may be a fault with the mains charger, and you may need to replace the mains charger.
  • R
    richardsonlauraAug 17, 2025
    What to do if there is no display on my Micro Direct MicroLab Medical Equipment?
    • K
      Kelly McdonaldAug 18, 2025
      If there's no display on your Micro Direct Medical Equipment, it could be that the charger is not connected, or the battery is exhausted. Connect the charger to the mains and leave the unit to fully charge. If this doesn't solve the issue, return the unit for servicing.
  • E
    Elizabeth JohnsonAug 20, 2025
    Why calibration procedure failed on Micro Direct MicroLab Medical Equipment?
    • H
      heatherlongAug 21, 2025
      There are several reasons why the calibration procedure might fail on your Micro Direct Medical Equipment: * The turbine may be faulty, so repeat the calibration procedure; if the problem persists, replace the turbine or return the unit for servicing. * The turbine might not be fitted tightly to the calibration syringe; ensure the syringe is fitted to the turbine, using an adapter if necessary. * The calibration syringe may not have an inspiratory seal, or the seal is leaking; ensure you are using the manufacturer's recommended syringe. * The shaft of the syringe is being pushed down; the syringe should be emptied and filled with one smooth stroke, avoiding pushing down on the shaft or banging at the end of each maneuver.
  • C
    cynthiaedwardsAug 25, 2025
    What to do if blows tracking ends abruptly on Micro Direct MicroLab Medical Equipment?
    • H
      Heather DayAug 25, 2025
      If the blow tracking ends abruptly on your Micro Direct Medical Equipment while the patient is still exhaling, the turbine may be sticking. Try cleaning the turbine in warm soapy water or a disinfecting solution. If the problem continues, a replacement turbine may be required.
  • Z
    zacharysmithAug 27, 2025
    How to fix a frozen display on Micro Direct Medical Equipment?
    • A
      angelawhiteAug 27, 2025
      If the display on your Micro Direct Medical Equipment freezes and the unit does not respond to key presses, it could be because multiple icons have been selected or accidentally pressed. To resolve this, hold the on/off button down for approximately 10 seconds until the unit switches off, and then turn it on again.
  • R
    Robert BishopAug 30, 2025
    What to do if the stylus doesn't register icons on my Micro Direct MicroLab?
    • N
      Nancy FrazierAug 30, 2025
      If the stylus does not register icons on the display of your Micro Direct Medical Equipment, the touch screen display may require calibration. Select the calibration check icon, choose touch screen, and follow the instructions.
  • B
    bennettelizabethSep 3, 2025
    Why is the paper not printing on my Micro Direct MicroLab Medical Equipment?
    • G
      garciamarySep 3, 2025
      There are a couple of reasons why the paper might not be printing on your Micro Direct Medical Equipment. First, check that the paper is housed correctly in the printer compartment by referring to the "paper loading" section of this manual and following the instructions. Second, ensure that you are using Micro Direct recommended thermal paper (see the Consumables/Accessories section).
  • A
    ariel45Sep 6, 2025
    What to do if my Micro Direct MicroLab Medical Equipment does not register a blow?
    • B
      Brittany RodriguezSep 6, 2025
      If your Micro Direct Medical Equipment does not register a blow, it could be due to a broken head assembly or cable. You should replace the head assembly or return the unit for servicing.
  • K
    Kelly BenitezSep 10, 2025
    Why are blows inverted on the display of my Micro Direct Medical Equipment?
    • A
      Anna SingletonSep 12, 2025
      If the blows are inverted on the display of your Micro Direct Medical Equipment, it is likely that the head assembly or cable is broken. Replacement of the head assembly or return of the unit for servicing is required.

Summary

Indications for Spirometry

Introduction

Contraindications

Conditions where suboptimal spirometry testing may occur or should be avoided.

Warning and Cautions

Indication for Use

Specifies the intended medical applications and patient age ranges for the spirometer.

General Safety Precautions

Overview

Main Menu Navigation

Explains how to navigate the main menu, access functions, and use help screens.

Getting Started

Turbine Transducer Connection

Details how to correctly connect the turbine transducer to the instrument for operation.

Patient Management

Ethnic Origin and Factor

Explains the application of ethnic origin and correction factors for predicted values.

Workflow and Patient Selection

Relaxed Spirometry

Relaxed Spirometry Results

Describes how to view and interpret the indices and graphs for relaxed spirometry tests.

Forced Spirometry

Forced Spirometry Results

Explains how to view, save, print, and add notes to forced spirometry test results.

Maximum Voluntary Ventilation

MVV Tidal Breathing

Instructs on performing initial tidal breathing maneuvers before the main MVV test.

MVV Maneuver Execution

MVV Test Quality Note

Provides notes on patient effort acceptability and the duration for a quality MVV maneuver.

MVV Test Completion

MVV ATS Quality Criteria

Explains the ATS criteria for a good MVV blow and reproducibility.

MVV Results Display

MVV Maneuver Selection

Describes how to select the best MVV maneuver and return to the main menu.

Calibration Check (Verification)

Spiro Calibration Check Procedure

Calibration Check Flow Rates

Describes performing calibration checks at low, required, and high flow rates.

Calibration Check Report

Calibration Error Interpretation

Details how to interpret calibration errors and troubleshooting steps if errors exceed limits.

Customization

System Options Configuration

Details system settings like language, date format, and printout headings.

Spirometry Options Configuration

Covers settings for spirometry modes, predicted value sets, and display preferences.

MVV Options Configuration

Details MVV settings like choice of predicted values and ambient temperature display.

Administration Mode

Administration Mode Functions

Explains functions available in admin mode, like enabling/disabling icons and changing access codes.

Paper Loading

Switching Off

Charging Procedure

PC Connection and SPCS Software

Spirometer Care and Handling

Product Lifetime and Precautions

Details essential precautions for operation and the designed product lifetime of the spirometer.

Cleaning Instructions

Provides detailed instructions for cleaning contaminated parts and the device.

Cleaning Accessories and Transducer

Accessory Cleaning Schedule

Specifies when and how to clean various accessories, including disposable items.

Transducer Cleaning Procedure

Details the step-by-step process for removing and cleaning the transducer.

Servicing

Troubleshooting Information

Safety Designation per IEC 60601-1

Electrical Safety Warnings

Highlights critical warnings regarding modifications, connections, and user interaction with electrical parts.

Electromagnetic Compatibility (EMC)

Symbols

Device Specifications

General and Display Specifications

Details general features, display type, power supply, battery, dimensions, and operating environment.

Spirometry Measurement Parameters

Lists all measured parameters for spirometry, including VC, FEV, PEF, and calculated ratios.

Test and Accuracy Specifications

Consumables and Supporting Products

ICD-10 Codes for Spirometry

Micro Direct MicroLab Specifications

General IconGeneral
Parameters MeasuredpH, Conductivity, Temperature, Dissolved Oxygen
DisplayLCD
ConnectivityUSB
Measurement ParameterspH, Conductivity, Temperature, Dissolved Oxygen
StandardsCE
pH Range0 - 14 pH
Power SupplyBatteries