EasyManua.ls Logo

MICRO-EPSILON TIM 160 - Page 83

Default Icon
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 83
Appendix | Industrial Process Interface (Optional)
thermoIMAGER TIM
Color Designation
Gray Interrupt
Green SCL (I
2
C)
Yellow SDA (I
2
C)
White 3,3 V
Brown GND
Shield GND
Fig. 40 Pin assignment connection cable industrial PIF
The industrial process interface offers the following inputs and outputs:
Designation Description max. range
1
/ status
A IN 1 / 2 Analog input 1 und 2 0 - 10 V
D IN 1 Digital input 24 V
AO1 / 2 / 3 Analog output 1, 2 and 3 0 - 10 V
Alarm output 1, 2 and 3 0 / 10 V
DO1 / 2 / 3 Relay output 1, 2 and 3
2
open/ closed (red LED on) / 0 ... 30 V, 400 mA
FS Fail-safe relay open/ closed (green LED on) / 0 ... 30 V, 400 mA
The voltage levels for the DI are: LOW = 0 ... 0.6 V /HIGH = 2 ... 24 V.
The process interface has an integrated fail-safe mode. This allows to control conditions like interruption of
cables, shut-down of the software etc. and to give out these conditions as an alarm.

Table of Contents

Other manuals for MICRO-EPSILON TIM 160