It is generally recommended that the user should not adjust the settings, and only do so after reading the
manual provided by the AC meter’s manufacturer. However, if the user wishes to reset the kWh reading, this is
relatively simple and is described below.
WARNING
Some appliances may cause the Power Pak to operate with a lower Power Factor (PF).
Operating products with a motor, like a saw or water pump, may drop the PF to 0.8 or lower. Operating with a
PF below 0.5 for many hours may reduce performance of the Power Pak. This is most common with failing
motors or some motors manufactured outside of North America. Check the PF by pressing
The Frequency and Power Factor and Demand button until the Power Factor (PF) is displayed.