EasyManua.ls Logo

Microsemi ATS-6501 T-Flex - Output Signals

Microsemi ATS-6501 T-Flex
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC 6501_Release V
ATS-6501 Users Guide
89
[external]
[communications] N/A
[locked] true
[signal] present
[internal]
[locked] true
[timescale]
[clocks]
[Cesium1]
[1_pps_present_slot_4_port_1] true
[communications] N/A
[id] 1365
[Cesium2]
[1_pps_present_slot_4_port_2] true
[communications] N/A
[id] 1559
[hp5071]
[can_communicate] false
[lns]
[locked] true
[ntp]
[locked] true
[source] internal refclock
[ocxo_freq_control] 2
[OK] 2013-08-08T14:28:03Z
Reference_type = Cesium
[external] not monitored
[hp5071]
[can_communicate] false
[internal] locked
[lns] locked
[locked] true
[ocxo_freq_control] 0
R. If the ATS-6501 has a 4393A Card that is actively making measurements the system will
report those measurements as they are computed for each channel. The system will
update the status when the ptd_avg expires and the averaged values are computed.
[tic_measurements]
[channel]
[31] 1.317307692300000e-08
[32] 1.461538461500000e-08
[33] 1.432692307700000e-08
[34] 1.916666666700000e-08
S. The system will report when the status message was reported to the user.
[time] 2013-08-08-14:30:26
T. The [unit] will display the system network information, serial number, the startup time
(when NTP Locked), the uptime since the last power cycle, reboot, or restart and the
software version running on the system, and the time the status command was executed.
[network]
[MAC] 00:30:96:00:00:98
[broadcast] 192.168.150.255

Table of Contents