Error
Code
Unit
Action
Causes Explanation
E10
In 7 minutes, the
water level
doesn’t change
with valves open
Unit will close
valve and stop
with Error code
display
Low Water
Pressure from
House Supply
If the washer fills very slowly, the water
pressure from the house might be too low.
If the water inlet valve isn't leaking and
there are no other symptoms this
problem does not need to be corrected.
Water inlet hose
Make sure that water faucet is turned on
and that the screens on the hoses are not
restricted.
Water inlet valve
(The voltage on
the water inlet
valve is normal)
If the water pressure is good, try cleaning
the screens inside the water inlet valve
hose connection ports. If those are clean
replace the water inlet valve.
Water level sensor
or
control switch
(No voltage on the
water inlet valve)
A water lever control switch controls how
much water enters the washing machine
by PCB. If the water level control switch is
defective, or more commonly, if the small
air pipe attached to the air bell restricted,
The switch will not be able to close the
electrical contacts to the washer fill valve.
CHECK THE AIR PIPE
CHECK THE WATER LEVERL SENSOR
CHECK THE PCB and the inner wire
between PCB and the sensor