Aqua Tempo Super II
40 201709
Midea Aqua Tempo Super II
Service Manual
8: pressure ratio and capacity demand
adjusting;
9: cooling low pressure limit frequency)
38
Defrosting process status
The first digit: T4 selection solution;
The second digit: scheme's range;
The third and fourth digits : defrosting time
39
EEPROM mismatch indicator:
1 : failure;
0 : no failure
40
Defrosting scheme
Actual value = value displayed
41
Initial frequency
Actual value = value displayed
42
Tc(+30)/Te(+25)
Actual value = value displayed
43
Online units statistic
Actual value = value displayed
44
Program version
Actual value = value displayed
45
---
-
Notes:
1. The fan speed index is related to the fan speed in rpm as described in Table 3-5.3 in Part 3, 5.6 Outdoor Fan Control.
2. Silent mode:
0: night silent mode; 1: silent mode; 2: super silent mode; 3: no silent mode.