Aqua Tempo Super II
201709 47
Part
4 - Diagnosis and Troubleshooting
3 Error Code Table
Displayed on main PCB and user interface
Inverter module A EEPROM mismatch
Displayed on main PCB and user interface
Inverter module B EEPROM mismatch
Displayed on main PCB and user interface
Power phase sequence error
Displayed on main PCB and user interface
Communication error between main PCB and wired
controller
Displayed on main PCB and user interface
Total water outlet temperature sensor (Tw) error
(displayed on master unit only)
Displayed on main PCB and user interface
Outlet water temperature sensor (Two) error
Displayed on main PCB and user interface
Air-side heat exchanger temperature sensor (T3) error
Displayed on main PCB and user interface
Outdoor ambient temperature sensor (T4) error
Displayed on main PCB and user interface
Displayed on main PCB and user interface
Water-side heat exchanger anti-freezing temperature
sensor1 (Taf1) error
Displayed on main PCB and user interface
Water-side heat exchanger anti-freezing temperature
sensor2 (Taf2) error
Displayed on main PCB and user interface
Number of units detected by wired controller has
decreased
Displayed on main PCB and user interface
Compressor discharge temperature sensor1 (Tp1) error
Displayed on main PCB and user interface
Compressor discharge temperature sensor2 (Tp2) error
Displayed on main PCB and user interface
Inlet water temperature sensor (Twi) error
Displayed on main PCB and user interface
Displayed on main PCB and user interface
Compressor discharge temperature sensor error
Displayed on main PCB and user interface
Total cooling outlet temperature sensor (Tz/7) error
Displayed on main PCB and user interface
Compressor discharge temperature protection
Displayed on main PCB and user interface
Compressor suction temperature protection
Displayed on main PCB and user interface
Power supply phase B Current protection
Displayed on main PCB and user interface
Power supply phase C Current protection
Displayed on main PCB and user interface
System A inverter module protection
Displayed on main PCB and user interface
System A inverter module protection
Displayed on main PCB and user interface
Condenser tube and Total cooling outlet high
temperature protection
Displayed on main PCB and user interface
Water-side heat exchanger inlet/outlet temperature
difference protection
Displayed on main PCB and user interface
Inlet water high temperature in cooling mode
Displayed on main PCB and user interface
System anti-freezing protection
Displayed on main PCB and user interface
Evaporator pressure low in cooling mode
Displayed on main PCB and user interface
Low-temperature protection of evaporator (manual
recovery)
Displayed on main PCB and user interface
Module high temperature protection
Displayed on main PCB and user interface
DC fan 1 module protection
Displayed on main PCB and user interface
DC fan 2 module protection
Displayed on main PCB and user interface