23
4.3 Error codes
Fault
Code
Category
Description
Debounce
Class
When
Checked
Criteria
Action After Fault
Debounced
E4
Sensor
Humidity
Error
W
Run
Control will run whole
cycle with cycle default
setting, and don’t need
dry the cloth with
humidity sensor, just
use timed drying.
Will run current cycle
without fault, log this
error code at the end
of cycle if EEPROM is
aviable or display it at
the end of cycle
E5
Sensor
Outlet
Temperature
Sensor Error
2 sec
C
Run
A/D Reading under
10(open) or over1000
(short)
1) heater off
2) Motor off
3) Go to Fault state
C9
Communicati
on error
110sec
C
Run
1) heater off
2) Motor off
3) Go to Fault state