- 7 -
MSG-36CRN1-QB8P MSG-36HRN1-QB8P
Ph-V-Hz
1, 220-240V~, 50Hz 1, 220-240V~, 50Hz
Capacity Btu/h
35000 35000
Input W
3550 3550
Rated current A
16.9 16.9
EER Btu/w.h
9.56 9.56
Capacity Btu/h
-----
38000
Input W
-----
4280
Rated current A
-----
18.8
COP W/W
-----
10.2
A
32 24.1
A
84 84/92
Model
NN37VAAMT ZR47K3-PFJ-522
Type
ROTARY ROTARY
Brand
泰国三菱 泰国三菱
Capacity Btu/h
39000 39000
Input W
3130/3240 3130/3240
Rated current(RLA) A
14.7/14.4 14.7/14.4
Locked rotor Amp(LRA) A
84/92 84/92
Thermal protector
15HM1637 15HM1637
Capacitor uF
60uF/
≥
400VAC 60uF/
≥
400VAC
Refrigerant oil ml
1300 1300
Model
YDK50-4E YDK50-4E
Brand
Welling Welling
Input W
76/67/54 76/67/54
Capacitor uF
33
Speed(hi/mi/lo) r/min
1260/1170/1000 1260/1170/1000
m3/h
1350/1200/1050 1350/1200/1050
dB(A)
52/49/45 52/49/45
Model
YDK100-6 YDK100-6
Brand
Welling Welling
Input W
169 169
Capacitor uF
55
Speed r/min
900 900
m
3
h
3000 3000
dB(A)
60 60
g
2450 2450
MPa
4.2 4.2
Liquid side/ Gas side mm
Φ
9.52/
Φ
16
Φ
9.52/
Φ
16
Max. refrigerant pipe length m
25 25
Max. difference in level m
10 10
℃
17-30 17-30
℃
18-45 -7 - 45
m
2
60~78 60~78
Model
Power supply
Cooling
Heating
Max. current
Starting current
Compressor
Indoor
fan motor
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat
different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.