EasyManuals Logo

Midea RG58D/BGEFU1 User Manual

Midea RG58D/BGEFU1
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
Specifications subject to change without notice.
DEFAULT VALUES OF INDOOR UNITS
Table 2—Default Values of Indoor Units
Description Remote Code Cassette Ducted Console
Auto-Start Function F1 ON ON ON
Heating Temperature Compensation F2 6C 6C 0C
Anti-Cold Air Function F3 NORMAL NORMAL NORMAL
Indoor Fan Motor Speed Control after Set Temperature is Reached F4 SET SPEED SET SPEED SET SPEED
Louver Angle Memory Function F5 N/A N/A N/A
Heating Only or Cooling and Heating Setting F6 CH CH CH
Cooling Temperature Compensation F7 -2C -2C -2C
Refrigerant Leakage Detection F8 ON ON ON
Cleaning Filter Reminder F9 OFF OFF OFF
Filter Replacement Reminder E1 OFF OFF OFF
Lowest Temperature Setting E2 17C 17C 17C
Highest Temperature Setting E3 30C 30C 30C
Special Anti-Cold Air Function Setting E4 N/A N/A N/A
Priority Setting of Heating or Cooling (Multi-Zone Systems only) E5 H H H
Network Address Setting E6 N/A N/A N/A
Capacity Code Selection E7 N/A N/A N/A
Twins Setting E8 N/A N/A N/A
Static Pressure Setting E9 N/A 0 N/A
POINT CHECK FUNCTION
Press LED on the remote controller three times and then press SWING three times within 10 seconds, the buzzer rings for 2 seconds and the air
conditioner enters the information enquiry status. Next, press LED
to search the information. Press SWING to search the remaining information.
When the air conditioner enters the enquiry information status, it displays the code name in 2 seconds (see Table 3).
Table 3—Information Codes
Enquiry Information Displaying Code Meaning
T1 T1 Return temperature
T2 T2 Indoor Coil temperature
T3 T3 Outdoor Coil temperature
T4 T4 Outdoor Air temperature
T2B Tb Indoor Coil Leaving temperature
TP TP Compressor Discharge temperature
TH TH IPM Heatsink temperature
Targeted Frequency FT Targeted Frequency
Actual Frequency Fr Actual Frequency
Indoor fan speed IF Indoor fan speed
Outdoor fan speed OF Outdoor fan speed
EXV opening angle LA EXV opening angle
Compressor continuous running time CT Compressor continuous running time
Causes of compressor stop ST Causes of compressor stop
Reserve A0
Reserve A1
Reserve .b0
Reserve .b1
Reserve .b2
Reserve .b3
Reserve .b4
Reserve .b5
Reserve .b6
Reserve .dL
Reserve Ac
Reserve Uo
Reserve Td