Installation
41
Repositioning the ducting
The motor unit can be rotated to allow
the
ducting to be fitted at the back of
the rangehood. This may be necessary
if the rangehood is being fitted in a
reduced height wall unit, for example.
Repositioning is carried out before
installing the rangehood.
The rangehood must be
disco
nnected from the mains.
Un
do the fixing screws on the front
panel of the rangehood housing and
remove the panel.
Un
do the screws from the cover on
the back of the rangehood housing
and remove the cover.
Unscrew the fixing screws on the
motor unit.
T
urn the motor unit towards the rear
and position the exhaust socket in
the cut-out in the back panel of the
rangehood housing. Ensure when
turning the motor unit that the
connection cable does not become
detached.
Secur
e the motor unit in its new
position.
Now secure the cover taken from the
back panel to the top of the housing.
Refit the fr
ont panel and secure it
using the screws.
...EXT model rangehoods
On appliances with an external motor
(..
.EXT models), the exhaust socket (not
the motor unit) needs to be
repositioned.
Unsc
rew the fixing screws and pull
the top and bottom sections of the
socket apart.
P
osition the top section of the socket
over the cut-out in the back panel of
the rangehood housing and attach
the bottom section to it from inside.
Secure the exhaust socket with the
fixing screws.