Safety clearances
31
Safety distance from the wall covering
If a wall covering is installed, a minimum safety distance must be maintained
between the countertop cut-out and the covering, since high temperatures can
damage these materials.
If the covering is made of a flammable material (such as wood), the minimum
distance between the countertop cut-out and the wall covering must be 50mm.
For coverings made of non-flammable materials (such as metal, natural stone,
ceramic tiles) the minimum safety distance between the countertop cut-out and
the wall covering is equal to 50mm minus the thickness of the covering.
For example: thickness of wall covering 15mm
50mm - 15mm = minimum distance of 35mm
Flush-mounted cooktops Cooktops with trim or bevelled
edges
a
Masonry
b
Wall covering dimension x = thickness of wall covering
c
Countertop
d
Countertop cut-out
e
Minimum distance to
flammable materials: 50mm
non-flammable materials: 50mm - dimension x